Part Number Hot Search : 
LS7184 MLL3827 40408 S2064 P6SMB68 V3023 1020C TS35P05G
Product Description
Full Text Search
 

To Download B2001RUI Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
  key features: ? 20w output power ? 4:1 input voltage range ? compact 1 x 2 inch case ? 2,500 vdc isolation ? high ef? ciency ? single & dual outputs ? remote on/off ? industry standard pin-out b2000rui compact, high isolation 4:1 input range, 20w dc/dc con vert ers series input parameter conditions min. typ. max. units input voltage range 24 vdc input 9.0 24.0 36.0 vdc 48 vdc input 18.0 48.0 72.0 input filter  (pi) filter reverse polarity input current 2.0 a short circuit input power 3,500 mw output parameter conditions min. typ. max. units output voltage accuracy 1.0 % output voltage balance dual output , balanced loads 0.5 % line regulation vin = min to max 0.5 % load regulation, single output iout = 0% to 100% 0.5 % load regulation, dual output iout = 0% to 100% 1.0 % ripple & noise (20 mhz) see note 1 75 mv p - p output power protection 120 % transient recovery time, see note 2 25% load step change 250 sec transient response deviation 3.0 % temperature coef? cient 0.02 %/c output short circuit continuous (autorecovery) general parameter conditions min. typ. max. units isolation voltage (input/output) 60 seconds 2,500 vdc isolation voltage (case/input(output) 1,600 vdc isolation resistance 500 vdc 1,000 m isolation capacitance 100 khz, 1v 1,200 pf switching frequency 330 khz environmental parameter conditions min. typ. max. units operating temperature range ambient -40 +25 +66 c operating temperature range case +105 c storage temperature range -40 +125 c cooling free air convection humidity rh, non-condensing 95 % rfi six-side shielded metal case physical case size 2.0 x 1.0 x 0.40 inches (50.8 x 25.4 x 10.2 mm) case material metal with non-conductive base (ul94-v0) weight 1.06 oz (30g) reliability speci cations parameter conditions min. typ. max. units mtbf mil hdbk 217f, 25c, gnd benign 560 khours absolute maximum ratings parameter conditions min. typ. max. units input voltage surge (1 sec) 24 vdc input -0.7 50.0 vdc 48 vdc input -0.7 100.0 lead temperature 1.5 mm from case for 10 sec 260.0 c internal power dissipation all models 4,500 mw caution: exceeding absolute maximum ratings may damage the module. these are not continuous operating ratings. electrical speci cations speci cations typical @ +25?, nominal input voltage & rated output current, unless otherwise noted. speci cations subject to change without notice. www.micropowerdirect.com micropower direct 292 page street suite d stoughton, ma 02072 usa t: (781) 344-8226 f: (781) 344-8481 e: sales@micropowerdirect.com w: www.micropowerdirect.com
model number input output over voltage protection (vdc) ef ciency (%, typ) max capacitive load (? max) fuse rating slow-blow (ma) voltage (vdc) current (ma) voltage (vdc) current (ma, max) current (ma, min) nominal range full-load no-load B2001RUI 24 9.0 - 36.0 879 50 3.3 5,500.0 0.0 3.9 89 10,000 2,000 b2002rui 24 9.0 - 36.0 957 50 5.0 4,000.0 0.0 6.8 90 6,800 2,000 b2003rui 24 9.0 - 36.0 980 22 12.0 1,670.0 0.0 15.0 88 1,000 2,000 b2004rui 24 9.0 - 36.0 968 22 15.0 1,330.0 0.0 18.0 89 680 2,000 b2005rui 24 9.0 - 36.0 968 65 5.0 2000.0 0.0 6.2 89 2,200 2,000 b2006rui 24 9.0 - 36.0 980 25 12.0 835.0 0.0 15.0 88 470 2,000 b2007rui 24 9.0 - 36.0 980 25 15.0 665.0 0.0 18.0 88 330 2,000 b2011rui 48 18.0 - 75.0 440 30 3.3 5,500.0 0.0 3.9 89 10,000 1,500 b2012rui 48 18.0 - 75.0 457 30 5.0 4,000.0 0.0 6.8 91 6,800 1,500 b2013rui 48 18.0 - 75.0 484 15 12.0 1,670.0 0.0 15.0 89 1,000 1,500 b2014rui 48 18.0 - 75.0 484 15 15.0 1,330.0 0.0 18.0 89 680 1,500 b2016rui 48 18.0 - 75.0 484 45 5.0 2000.0 0.0 6.2 89 2,200 1,500 b2016rui 48 18.0 - 75.0 490 15 12.0 835.0 0.0 15.0 88 470 1,500 b2017rui 48 18.0 - 75.0 490 15 15.0 665.0 0.0 18.0 88 330 1,500 micropower direct we power your success - for less! 292 page street ste d stoughton, ma 02072 ? tel: (781) 344-8226 ? fax: (781) 344-8481 ? e-mail: sales@micropowerdirect.com www.micropowerdirect.com model selection guide mechanical dimensions mechanical notes: all dimensions are typical in inch es (mm) tolerance x.xx = ?.01 (?.25) pin single dual pin single dual 1 +vin +vin 4 trim common 2 -vin -vin 5 -vout -vout 3 +vout +vout 6 remote on/off remote on/off pin con nec tions remote on/off (optional, see below) parameter min max units supply on 3.0 12 or open vdc supply off 0.0 1.2 vdc standby input current 5 ma typical control common referenced to neg. input (pin 2) notes: 1. when measuring output ripple, it is recommended that an external 1.0 ? ceramic capacitor be placed from the +vout pin to the -vout pin for single output units and from each output to common for dual output units. 2. transient recovery is measured to within a 1% error band for a load step change of 75% to 100%. 3. operation at no-load will not damage these units. however, they may not meet all speci cations. 4. dual output units may be connected to provide a 10 vdc, 24 vdc or 30 vdc output. to do this, connect the load across the positive (+vout) and negative (-vout) outputs and oat the output common. 5. with the addition of a simple input pi lter, the unit should meet the conducted emissions requirements of en55022 class a. typical component values would be 2.2 ?/100v for the two capacitors and 12 ? for the inductor. the lter components should be mounted as close to the unit as possible. 6. it is recommended that a fuse be used on the input of a power supply for protection. see the table above for the correct rating. a simple external circuit may be used to adjust the converter output. to adjust the output down, connect a 5%, 3w resistor between the plus output pin and the vout trim pin. to adjust the output up, connect a 5%, 3w resistor between the minus output pin and the vout trim pin. for up/down trimming capability, con- nect a 10 kw potentiometer between the plus and minus outputs with the wiper arm connected to the vout trim pin. care should be taken that the maximum output power of the unit does not exceed the maximum rating. output trim (single output models) trim down -5% -10% units vout = 11.400 10.800 vdc rtrim - down = 38.591 5.264 k  trim up +5% +10% units vout = 12.600 13.200 vdc rtrim - up = 63.489 22.094 k  derating curve


▲Up To Search▲   

 
Price & Availability of B2001RUI

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X